Zahlungsart: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
---|---|
Minimum der Bestellmenge: | 1 Set/Sets |
Lieferzeit: | 10 Tage |
Modell: KH-1000GF
2.Genset Technical Data: | ||||||||
Gensets model | KH-1000GF | |||||||
Prime power | 1000KW/1250kVA | |||||||
Stangby power | 1100KW/1375KVA | |||||||
Rated speed | 1500RPM | |||||||
Output frequency | 50Hz | |||||||
Power Factor | 0.8(lagging) | |||||||
Phase | 3 | |||||||
Rated voltage | 400V/230V | |||||||
Noise dB(A) 7m | 70 | |||||||
Dimensions(mm) (L×W×H) | 9000×3000×3400 | |||||||
Genset Weight(kg) | 16230 | |||||||
Prime Power: | ||||||||
This rating is for the supply of continuous electrical power (at variable load). There is no limit on the annual hours of operation and 10% overload power can be supplied for 1 hour in 12. | ||||||||
Standby power: | ||||||||
This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted. | ||||||||
Rated voltage : | ||||||||
Available with customer requirements. | ||||||||
3. Specification of diesel engine: | ||||||||
Engine brand | Perkins | |||||||
Engine model | 4012-46TWG2A | |||||||
Number of Cylinders | 12 | |||||||
Cylinder arrangement | 12 V type 60 | |||||||
Cycle | Four stroke | |||||||
Aspiration | Turbo After-Water cooling | |||||||
Bore×Stroke (mm×mm) | 160 x 190 | |||||||
Displacement (Liter) | 45.842 | |||||||
Compression Ratio | 13.6:1 | |||||||
Speed Governor | Electrical | |||||||
Cooling System | Forced Water Cooling Cycle | |||||||
Speed Stability (%) | ≤1% | |||||||
Total lubrication system capacity (L) | 177 | |||||||
Fuel Consumption at 100% Load (L/H) | 196 | |||||||
Starting Method | DC24V | |||||||
4. Specification of alternator | ||||||||
Alternator brand | Kaihua | |||||||
Alternator model | KH404G | |||||||
Number of Phase | 3 | |||||||
Connecting Type | 3 Phase and 4 Wires | |||||||
Number of Bearing | 1 | |||||||
Protection Grade | IP21 | |||||||
Altitude | ≤1000m | |||||||
Exciter Type | Brushless ,Self-exciting, AVR automatic voltage regulating,100% Copper winding wire | |||||||
Insulation Class | H | |||||||
Telephone Influence Factor (TIF) | ≤50 | |||||||
THF | ≤2% | |||||||
Voltage Regulation, Steady State | ≤±1% | |||||||
Transient State Voltage | ≤-15%~+20% | |||||||
5. Specification of Control Panel(with GU controller) | ||||||||
The control panel is AMF LCD control panel, with the display of voltage,current, frequency, water temperature, oil pressure. The genset with low oil pressure,high water temperature,over speed,over load protection function. | ||||||||
6. Standard scope of supply including : | ||||||||
(1) Brand new Perkins diesel engine. | ||||||||
(2) Brand new Kaihua AC brushless alternator IP21. | ||||||||
(3) Radiator: 40°C.Ambient temperature mounted on skid. 40°C | ||||||||
(4) AMF LCD control Panel. | ||||||||
(5) Three phase:400V,single phase:230V , 50HZ1500RPM, 0.8PF. | ||||||||
(6) Standard Accessories(such as operation manual,certificate of conformity,shock absorber, battery, connector wire of battery and so on). |
Produktgruppe : Importieren der Marke Diesel-Generatoren > UK Parkins OEM-Diesel-Generatoren