Zahlungsart: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
---|---|
Minimum der Bestellmenge: | 1 Set/Sets |
Lieferzeit: | 15 Tage |
Modell: KH-800GF
1. Specification of genset | ||||||||
Gensets model | KH-800GF | |||||||
Prime power | 1000KVA/800KW | |||||||
Standby power | 1100KVA/880KW | |||||||
Rated Voltage | 400/230V | |||||||
Rated frequency(HZ) | 50 | |||||||
Rated Speed | 1500rpm | |||||||
Power Factor | 0.8(lagging) | |||||||
Dimensions(mm) (L×W×H) | 4500X1850X2350 | |||||||
Net Weight(kg) | 6500 | |||||||
2. Specification of diesel engine | ||||||||
Engine brand | Cummins | |||||||
Engine model | KTA38-G5 | |||||||
Number of Cylinders | 12 | |||||||
Cylinder arrangement | In V | |||||||
Cycle | Four stroke | |||||||
Aspiration | Turbo,air/water cooling | |||||||
Fuel System | PT type fuel pump,EFC | |||||||
Bore×Stroke (mm×mm) | 159 x 159 | |||||||
Displacement (Liter) | 37.8 | |||||||
Compression Ratio | 13.0:1 | |||||||
Speed Governor | Electronic | |||||||
Cooling System | Forced Water Cooling Cycle | |||||||
Total lubrication system capacity (L) | 201 | |||||||
Starting Method | DC24V electrical starting | |||||||
3. Specification of alternator | ||||||||
Alternator brand | Stamford | |||||||
Alternator model | LVI634E | |||||||
Number of Phase | 3 | |||||||
Connecting Type | 3 Phase and 4 Wires | |||||||
Number of Bearing | 1 | |||||||
Protection Grade | IP23 | |||||||
Altitude | ≤1000m | |||||||
Exciter Type | Brushless ,Self-exciting, AVR automatic voltage regulating,100% Copper winding wire | |||||||
Insulation Class | H | |||||||
Telephone Influence Factor (TIF) | ≤50 | |||||||
THF | ≤2% | |||||||
Voltage Regulation, Steady State | ≤±1% | |||||||
Transient State Voltage | ≤-15%~+20% | |||||||
4. The components of the generator set | ||||||||
1)Cummins engine 2)Stamford alternator 3)Automatic start control panel | ||||||||
5.General Features: | ||||||||
Cummins Engine | ||||||||
Radiator 40°C max, fans are driven by Belt, with safety guard | ||||||||
12V charger alternator | ||||||||
Stamford Alternator | ||||||||
Absorber | ||||||||
Dry type air filter, fuel filter, oil filter | ||||||||
Main line circuit breaker | ||||||||
Standard control panel | ||||||||
Ripple flex exhaust pipe, exhaust siphone, flange, muffler | ||||||||
12V*2 batteries, rack and cable | ||||||||
User manual | ||||||||
6. Specification of control Panel | ||||||||
The control panel is AMF control panel, with the display of voltage,current, frequency, water temperature, oil pressure. The genset with low oil pressure,high water temperature,over speed,over load protection function. | ||||||||
The features of controller: | ||||||||
GU620A is a new generation Automatic control module for single Genset, which adopts bran-new outline configuration, focus on the requirements of customers, and perfectly improves the performance of controller. It fully meets the auto control requirements of different kinds of Genset for user or special assembly factory. | ||||||||
The module also monitors and protects the engine, indicating operational status, fault conditions and metering on the front panel LCD and LED’s. |
Produktgruppe : Dieselaggregate Power By CUMMINS Motor