Modell: KH-500GF
1. Specification of genset | ||||||||
Gensets model | KH-500GF | |||||||
Prime power | 500KW | |||||||
Rated Voltage | 380/220V | |||||||
Rated frequency(HZ) | 50 | |||||||
Rated Speed | 1500rpm | |||||||
Power Factor | 0.8(lagging) | |||||||
Dimensions(mm) (L×W×H) | 3400x1380x2050 | |||||||
Net Weight(kg) | 4050 | |||||||
2. Specification of diesel engine | ||||||||
Engine brand | VOLVO | |||||||
Engine model | TWD1643GE | |||||||
Air Intake System | Turbocharged, Water charge Air Cooling | |||||||
Fuel System | Elec. Injection, Elec. Fuel System | |||||||
Cycle | Four stroke | |||||||
Cylinder Arrangement | 6 in line | |||||||
Displacement | 16.12L | |||||||
Bore×Stroke (mm×mm) | 144 x 165 | |||||||
Compression Ratio | 16.5:1 | |||||||
Rated RPM | 1500rpm | |||||||
Cooling System | Forced Water Cooling Cycle | |||||||
Max. Standby Power at Rated RPM | 596KW/811HP (with fan) | |||||||
Starting Method | DC24V electrical starting | |||||||
Exhaust System | ||||||||
Exhaust Gas Flow | 111.8m3/min | |||||||
Exhaust Temperature | 463°C | |||||||
Max Back Pressure | 10kPa | |||||||
Air Intake System | ||||||||
Max Intake Restriction | 5kPa | |||||||
Burning Capacity | 46.96 m3/min | |||||||
Air Flow | 780m3/min | |||||||
Fuel System | ||||||||
100%(Prime Power) Load | 199 g/KWh | |||||||
75%(Prime Power) Load | 196 g/KWh | |||||||
50%(Prime Power) Load | 196 g/KWh | |||||||
Total Fuel Flow | 190L/h | |||||||
Oil System | ||||||||
Total Oi l Capacity | 48L | |||||||
Oil Consumption | 0.11L/h | |||||||
Engine Oil Tank Capacity | 42L | |||||||
Oil Pressure at Rated RPM | 300-650kPa | |||||||
Cooling System | ||||||||
Total Coolant Capacity | 128L | |||||||
Thermostat | 82-92°C | |||||||
Max Water Temperature | 103°C | |||||||
3. Specification of alternator | ||||||||
Alternator brand | Engga | |||||||
Alternator model | EG355L-500N | |||||||
Excitation | Brushless ,Self-exciting, AVR automatic voltage regulating,100% Copper winding wire | |||||||
Winding pitch | 2/3 pitch | |||||||
Poles | 4 | |||||||
Bearing | 1 | |||||||
Stator winding | 12 | |||||||
Insulation | H | |||||||
Protection | IP21 | |||||||
Duty type | Continuous | |||||||
AVR type | WT-2 | |||||||
Base line | Fly wheel | |||||||
Temperature rise | <125 Degree | |||||||
Overload (100% load) | 110% load 1H | |||||||
Waveform THD | <5% | |||||||
Adjustment for Voltage | AVR | |||||||
Adjustment Ratio for Voltage | ±5% | |||||||
Voltage regulation | ±1% | |||||||
No load voltage waveform | <2% | |||||||
WaveformTIF | < 50 | |||||||
4. Specification of control Panel(with GU620A controller) | ||||||||
The control panel is AMF control panel, with the display of voltage,current, frequency, water temperature, oil pressure. The genset with low oil pressure,high water temperature,over speed,over load protection function. | ||||||||
The features of GU620A controller: | ||||||||
GU620A is a new generation Automatic control module for single Genset, which adopts bran-new outline configuration, focus on the requirements of customers, and perfectly improves the performance of controller. It fully meets the auto control requirements of different kinds of Genset for user or special assembly factory. | ||||||||
The module also monitors and protects the engine, indicating operational status, fault conditions and metering on the front panel LCD and LED’s. |
Produktgruppe : Importieren der Marke Diesel-Generatoren > Diesel Generator Sets macht von Volvo